NG-CANCAN Remote Targeting Electroporation: Impact of Pulse Duration and Protocol Delivery Frequency
DOI:
10.48324/dandi.001277/0.250701.1610
10.48324/dandi.001277/0.250701.1610
ID: 001277
0.250701.1610
0.250701.1610
Contact Silkuniene, Giedre
File Count 49
Size 23.2 GB
Created July 1, 2025
Last update July 1, 2025
Licenses: spdx:CC-BY-4.0
Access Information: dandi:OpenAccess
Experiments were conducted using a four-electrode array with an inter-electrode spacing of 10 mm. The electrode array was positioned at the bottom of the well plate (0 mm). Pulse durations of 300 ns, 600 ns, and 900 ns were tested. Depending on the pulse duration, the protocol consisted of 18 packets for 300 ns pulses, 9 packets for 600 ns pulses, or 6 packets for 900 ns pulses, delivered at...
Funding information
National Institutes of Health
- Award Number: 1R21EY034258
Anatomy
No anatomical information provided.
This Dandiset does not specify which brain regions or anatomical structures it covers. Adding indexed anatomy (e.g. UBERON terms) in the metadata editor makes this dataset discoverable by anatomical location.
Related resources
Assets Summary
Associated Projects
Targeted Neuromodulation by Nanosecond Pulsed Electric Fields